The TRC-NW8 is capable of non-mydriatic colour, red free and fluorescein angiography. The Topcon TRC-NW8 is one of the most advanced cameras from our non-mydriatic camera range. It offers a truly versatile camera capable of non-mydriatic colour & red free angiography.

Ključne funkcije

  • Color photography and red-free photography*, FA photography** and FAF photography***
  • 30° and 45° angle available
  • Wide 85° angle of coverage with internal fixation
  • Auto-focus & auto-shoot
  • Panoramic overview with optional mosaic module
  • Small pupil capability down to 3.3mm
  • Anterior support
  • Stereo photography

    *TRC-NW8F Plus model: Digital Red-free
    **Only for TRC-NW8F and TRC-NW8F Plus model
    ***Only for TRC-NW8F Plus model

The Topcon TRC-NW8 is one of the most advanced cameras from our non-mydriatic camera range. It offers a truly versatile camera capable of non-mydriatic colour & red free angiography.

True optical red-free photography

Topcon has developed an innovative feature on TRC-NW8/TRC-NW8F: True optical Red-free capability with an actual red-free filter. This feature allows for high resolution red-free images acquisition.
*TRC-NW8F plus: Digital Red-free

Fundus
The TRC-NW8 non-mydriatic fundus camera comes with a Nikon D-700, 16 megapixel digital camera, enabling the user to zoom in on the finest detail. This particular camera offers a 45 degree angle which covers fovea and macula. Nine fixation targets enable to shoot nine images which can be collated using IMAGEnet i-base to enable a complete overview (IMAGEnet i-base auto-mosaic is needed for this function). Stereo photography and a real red free filter is a standard option on TRC-NW8.

Ease of use
TRC-NW8 is joystick operated with a minimum of buttons to push. The auto-shoot, auto-focus and auto-exposure ensure sharp, clear images with a lot of detail. In one movement the practitioner can switch between colour, red free images and fluorescein images.

Patient comfort
The low flash intensity offers the patient increased comfort, which enables the practitioner to shoot more images in less time. A minimum pupil size of 3.3mm is needed.

NHS compliant
The TRC-NW8 has been approved for the national programm of the NHS in the UK for screening of diabetic retinopathy.

Angle of coverage 45º
Working range 40,7 mm
Pupil diameter for photography 4,0mm or more / 3,3mm or more when the small pupil diaphragm is used
Type of photography Color photography and red-free photography*, FA photography** and 
FAF photography***
Patient diopter correction range Without correction lens: -13D to +12D (where split lines are used)
  With minus correction lens: -33D to -12D
  With plus correction lens: +9D to +40D
Auxiliary function for photography Auto focus function 
(Used only in the split line working range. This can be turned ON/OFF)
Fixation Target

Internal / External fixation target can be selected

 

Internal fixation target

  Centre / Periphery
  Right/left eye automatic detection
  Optional position presetting function
Base movement Back-forth: 46mm, Right-left: 100mm, Up-down: 30mm
Chinrest movement 67mm
Power source Frequency: 50/60Hz Voltage: AC110-240V
Weight 23,5kg (TRC-NW8/TRC-NW8F), 23,8kg (TRC-NW8F plus)
Dimensions 274mm(W) x 508mm(D) x 536-566mm(H)
Power consumptions 400VA(Maximum), 100VA(Normal)

*TRC-NW8F plus model: Digital Red-free
**Only for TRC-NW8F and TRC-NW8F plus model
***Only for TRC-NW8F plus model

TRC-NW8_Series_2019